CRA Harmonised Standards Tracker, October 2026: Which Standard Applies to Your Product and Where It Stands

CRA Harmonised Standards Tracker, October 2026: Which Standard Applies to Your Product and Where It Stands
The honest short answer for November 2026 is this: no standard written for the Cyber Resilience Act (CRA) has been cited in the Official Journal, so none gives you the legal shortcut known as the presumption of conformity yet. But a lot has moved, and which standard matters to you depends on what you build.
This post is a working tracker. It lists where the main standards stand by product category, explains why the date on the calendar is not the date that matters, and sets out what to plan for each CRA class. It builds on our earlier explainers on the presumption of conformity and the ETSI public enquiry, so we will not repeat the basics.
Statuses below come from a third-party tracker (securehabits.nl, October 2026) and the independent cyberresilienceact.eu guide. Standards move week to week. Before you rely on a status, check it against the CEN-CENELEC and ETSI work programmes or your national standards body.
The date that matters is citation, not delivery
Two dates get confused. The first is when the standards bodies deliver drafts to the Commission under standardisation request M/606. The second is when a standard is cited in the Official Journal. Only the second gives you the presumption of conformity under Article 27: if you apply a cited standard, your product is presumed to meet the matching essential requirements.
On the first date, there has been a slip. In early July 2026 the Commission proposed a draft amendment to M/606 that moved the 2026 drafting deadlines by two months. Types A and B (horizontal and vulnerability-management standards) moved from 30 August to 31 October 2026, and type C (product-specific) from 30 October to 31 December 2026. The remaining horizontal standards are due 30 October 2027.
The 31 October date has just passed. As of the last update we could verify, the amendment was proposed rather than adopted, so confirm whether it was adopted and whether the drafts were delivered before you plan around either. The substantive CRA obligations are unaffected and still apply from 11 December 2027.
Horizontal standards: the base layer
These apply across product categories. The tracker lists them as follows.
| Standard | Scope | Stage |
|---|---|---|
| EN 40000-1-1 | Vocabulary | Adopted |
| EN 40000-1-2 | Principles, risk management, lifecycle | Adopted |
| EN 40000-1-3 | Vulnerability handling | Formal vote pending |
| EN 40000-1-4 | Generic security requirements | prEN draft |
If you do only one thing, read EN 40000-1-2 on risk management and the draft of EN 40000-1-3 on vulnerability handling. They apply to every category, and they line up with work you need to do anyway: the Article 13 risk assessment and your vulnerability handling process.
Vertical standards: find your product category
The product-specific standards are where the status varies most. The ETSI EN 304 6xx series covers 17 categories.
| Standard | Product category | Stage |
|---|---|---|
| EN 304 618 | Password managers | EN draft, vote closed, results pending |
| EN 304 619 | Anti-malware | EN draft, vote closed, results pending |
| EN 304 623 | Boot managers | EN draft, vote closed, results pending |
| EN 304 627 | Routers, modems, switches | EN draft, vote closed, results pending |
| EN 304 631 | Virtual assistants | EN draft, vote closed, results pending |
| EN 304 632 | Smart home | EN draft, vote closed, results pending |
| EN 304 633 | Connected toys | EN draft, vote closed, results pending |
| EN 304 634 | Wearables | EN draft, vote closed, results pending |
| EN 304 635 | Hypervisors and container runtimes (Class II) | EN draft, vote closed, results pending |
| EN 304 636 | Firewalls and IDS/IPS (Class II) | EN draft, vote closed, results pending |
| EN 304 617 | Browsers | prEN vote, closes by mid-November |
| EN 304 620 | VPN | prEN vote, closes by mid-November |
| EN 304 621 | Network management | prEN vote, closes by mid-November |
| EN 304 622 | SIEM | prEN vote, closes by mid-November |
| EN 304 624 | PKI | prEN vote, closes by mid-November |
| EN 304 625 | Network interfaces | prEN vote, closes by mid-November |
| EN 304 626 | Operating systems | prEN vote, closes by mid-November |
Beyond ETSI, the picture is similar but earlier-stage:
- Semiconductors and secure hardware: EN 40001-3 (microprocessors and microcontrollers), EN 40002-3 (tamper-resistant), and EN 40003-3 (smartcard and secure element platforms) are at EN draft stage. EN 40004-3 (FPGAs and ASICs) is at prEN vote.
- Identity and devices: EN 40000-10 (identity and privileged access management), EN 40000-11 (hardware with security boxes) and EN 18330 (smartcards, application layer) are at EN draft stage.
- Operational technology: the EN 50770 series from CLC/TC 65X, covering industrial firewalls, IDS/IPS, network management, network interfaces, VPN, routers and switches, and SIEM, is at prEN draft. Related IEC 62443 amendments are further along for 62443-4-1 and 4-2.
The pattern is clear. Consumer and network categories are closest. Industrial and hardware categories are a step behind. If you build industrial equipment, our post on IEC 62443 and the CRA explains how much of your existing work carries over.
What to plan, by CRA class
How much the missing citation hurts depends on your class.
| CRA class | Conformity route | What the standards gap means for you |
|---|---|---|
| Default | Internal control (module A), with or without standards | Little. You self-assess either way. Standards help you structure the evidence but are not a gate. |
| Important Class I | Internal control only if relevant harmonised standards, common specifications or a European certification scheme are fully applied. Otherwise generally a notified body. | This is the pressure point. If no suitable standard is cited in time, you may need a notified body. Plan for that possibility now. |
| Important Class II and Critical | Generally third-party assessment or certification | Standards matter less as a shortcut and more as the technical basis the assessor will use. Capacity at notified bodies is the bigger constraint. |
Notified body rules have applied since 11 June 2026, but member states are still designating bodies. We covered that bottleneck in our post on notified body capacity. The practical lesson for Class I makers is to avoid betting everything on a citation arriving before December 2027.
What to do this month
Work out whether you are Default, Important Class I or II, or Critical, and which row above is yours. If you are unsure, start with the product class guide.
Request the drafts through your national standards body and follow the CEN-CENELEC and ETSI work programmes. Read the horizontal pair first: EN 40000-1-2 and EN 40000-1-3.
Map your current security process to the draft requirements. Gaps you find now are cheap. Gaps found after citation are not.
Risk assessment, SBOM, technical documentation, vulnerability handling and update mechanisms are required whatever the standards say.
Keep a contingency plan and budget for third-party assessment, and talk to prospective bodies early.
Votes close in mid-November and results from the earlier votes are pending. Re-check the tracker each month.
The bottom line
Standards are a route to compliance, not the obligation itself. The obligations apply from 11 December 2027 whether or not a standard is cited, and for most manufacturers the sensible move is to build to the drafts, document the reasoning, and keep a fallback ready if citation arrives late.
Can I claim presumption of conformity today?
No. According to the trackers we checked, no CRA-related standard is cited in the Official Journal yet, so Article 27 presumption of conformity is not available for any of them.
Do I have to wait for the final standard before I start?
No. The drafts are a good guide to what will be expected, and much of the work, such as risk assessment, SBOM and vulnerability handling, is required whatever the final text says.
Was the 31 October 2026 deadline met?
We could not confirm it at the time of writing. The extension to 31 October was proposed in July and, as of the last update we could verify, was not yet adopted. Check the Commission and standards body announcements for the current position.
Which standard applies if my product is not on the list?
Start with the horizontal standards, which apply across categories. A product outside the Annex III and IV categories is generally a Default product and can follow the internal control route.
Related reading

What the European Refrigeration Attacks Demand of CRA-Ready Controller Manufacturers
The October-November 2026 European supermarket freezer attacks expose exactly the design failures the CRA's Annex I was written to prevent. Here's what they demand of manufacturers.
The New Product Liability Directive Treats Software as a Product: What It Means Next to the CRA
From 9 December 2026 the revised Product Liability Directive expressly covers software, including firmware and AI systems. It arrives a year before full CRA application. Here is how the two fit together, and which records protect you.
One Incident, Four Clocks: CRA, NIS2, GDPR and DORA Reporting Deadlines Side by Side
A single security incident can start reporting clocks under the CRA, NIS2, GDPR and DORA at once. Here are the deadlines side by side, a worked example, and how to build one intake that feeds all the tracks.